Key takeaways

  • This is usually not an emergency, but it does not fix itself and it gets worse if you leave it.
  • Most likely cause: Weak or failed thermocouple.
  • Do this first: Follow the label on the heater to relight the pilot once, exactly as printed.
  • Call right away if you smell gas near the heater. Leave and call the gas utility.
  • The repair starts with: Test the thermocouple output and inspect the pilot flame shape.

What it is

Pilot light that won't stay lit A pilot light that won't stay lit means the gas water heater's flame goes out shortly after lighting, usually because the thermocouple no longer senses heat well enough to keep the gas valve open.

It is not urgent on its own, but stop relighting after one attempt and leave the house immediately if you smell gas at any point.

The short answer

A pilot that lights and then dies within seconds is almost always a failing thermocouple. The thermocouple senses the flame and tells the gas valve to stay open, and when it weakens the valve shuts down as a safety measure. Other common causes are a dirty pilot orifice, a blocked flue or air intake, and a failed gas control valve. If you smell gas at any point, stop relighting and leave the house.

What it usually means

These are the causes we find most often, ranked from most likely to least.

  1. 1

    Weak or failed thermocouple

    Most likely

    The most common single cause. It is an inexpensive part with a short replacement time.

  2. 2

    Dirty pilot tube or orifice

    Common

    Dust and combustion residue starve the pilot flame so it cannot heat the sensor.

  3. 3

    Blocked flue or restricted combustion air

    Common

    A blocked vent pushes exhaust back down and smothers the pilot. This one also carries a carbon monoxide risk.

  4. 4

    Failed gas control valve

    Less common

    The valve no longer holds open even with a healthy signal from the thermocouple.

  5. 5

    Draft in the utility space

    Occasional

    An open door, a nearby vent, or a poorly sealed room blows the pilot out.

What to do right now

  1. 1Follow the label on the heater to relight the pilot once, exactly as printed.
  2. 2Check for obvious drafts near the burner compartment and close them off.
  3. 3Look at the flue for visible blockage, soot, or disconnection.
  4. 4If it will not hold after one attempt, stop. Repeated relighting does not fix a failed sensor.

When it is an emergency

  • You smell gas near the heater. Leave and call the gas utility.
  • There is soot around the burner or a carbon monoxide alarm has sounded.
  • The flue pipe is loose, rusted through, or disconnected.

What the fix involves

Most of these visits end with a thermocouple replacement and a cleaning of the pilot assembly. Where the flue is the problem, the venting gets corrected before the heater goes back in service, because a heater that cannot exhaust safely should not run.

  1. 1Test the thermocouple output and inspect the pilot flame shape.
  2. 2Clean the pilot assembly and orifice.
  3. 3Inspect the flue and combustion air path for blockage.
  4. 4Replace the thermocouple or gas control valve, then verify a stable flame.

What drives the cost

Every job is quoted before work begins. These are the factors that move the number on this kind of repair.

  • Thermocouple replacement versus gas valve replacement
  • Whether flue or venting corrections are needed
  • Age of the heater and parts availability
  • Access to the burner compartment

Licenses, credentials, and company proof

  • Colorado Master Plumber
    License MP-18927
  • Colorado State Plumbing Contractor
    License 2110
  • Family Owned & Operated
    Serving Denver since 2006, 20 years
  • Better Business Bureau
    Accredited Business, A+ rating
  • Angie's List Super Service Award
    2012 through 2017
  • Serving Denver since 2006
    Residential and commercial properties across the metro

Tell us what is happening

Send the details and we will get back to you with next steps and a free quote. If it is urgent, calling is faster.

Get A Free Quote

We reply fast. Same day when possible.

Name
Email
Phone Number
How did you hear about us?
What services are you interested in?
Message

Before you book: pricing, timing, and guarantees

Straight answers on what water heater pilot won't stay lit work costs, how fast we can get out, and what stands behind the repair.

Stop guessing and get it diagnosed

Family owned, licensed Colorado master plumbers serving the Denver metro since 2006.

Call Afford-A-Rooter Plumbing at (720) 296-7972.